One of our customers is replacing a Telecrane F24-6D with a new INMOTION K606 Radio Control System. In order to easily and correctly wire the new K606 our technician provided a cross reference of the Telecrane F24-6D wires.
Cross Reference Wires for Telecrane F24-6D and INMOTION K606
| Telecrane F24-6D | INMOTION K606 |
|---|---|
| 1 | 3 |
| 2 | 2 |
| 3 | 4 |
| 4 | 5 |
| 5 | 6, 8, 10, 12 |
| 6 | 7 |
| 7 | 11 |
| 8 | 9 |
| 9 | 13 |
| 10 | 14 |
| 11 | 15 |
| 12 | 16 |
| 13 | 17 |
| 14 | 18 |
| 15 | 19 |
| 16 | 20 |
| 17 | 21 |
| 18 (if used) | 22 |
| 19 (if used) | 23 |